View Issue Details [ Jump to Notes ] | [ Print ] | ||||||||
ID | Project | Category | View Status | Date Submitted | Last Update | ||||
0009023 | ParaView | Bug | public | 2009-05-13 20:08 | 2011-01-13 17:00 | ||||
Reporter | Alan Scott | ||||||||
Assigned To | Utkarsh Ayachit | ||||||||
Priority | high | Severity | major | Reproducibility | always | ||||
Status | closed | Resolution | fixed | ||||||
Platform | OS | OS Version | |||||||
Product Version | |||||||||
Target Version | 3.6 | Fixed in Version | 3.6 | ||||||
Summary | 0009023: Plots manual min/max has issues | ||||||||
Description | ParaView trunk, XP, local server. * Open disk_out_ref.exo, all variables, apply. * Calculator. Name the result TempSmall, in the formula use Temp/1000. Apply. (not sure if this step is needed). * Plot over line. Apply. * Display tab, turn off everything other than TempSmall. * Plot/ Properties. Left Axis, Layout. "Use Logarithmic Scale when Available" == ON. "Specify The Axis Range" == ON. Minimum == 5e-5, Maximum == 1. OK. <<Bug>> Note that the min has been changed to 1.0e-4. We have lost data. <<Bug>> Note that we have lost all ticks, including the maximum. This really needs to be fixed for 3.6. | ||||||||
Tags | No tags attached. | ||||||||
Project | |||||||||
Topic Name | |||||||||
Type | |||||||||
Attached Files | |||||||||
Relationships | |
Relationships |
Notes | |
(0016437) Utkarsh Ayachit (administrator) 2009-05-14 10:35 |
setBestFitGenerated was required to ensure that the us specified range was used. Fixed logic in the sub-label placement code for log-scales to correctly place values. Also decreasing the minimum log value very low, otherwise it was overlapping labels for values < 1e-4. /cvsroot/ParaView3/ParaView3/Servers/ServerManager/vtkSMChartOptionsProxy.cxx,v <-- Servers/ServerManager/vtkSMChartOptionsProxy.cxx new revision: 1.5; previous revision: 1.4 /cvsroot/ParaView3/ParaView3/VTK/GUISupport/Qt/Chart/vtkQtChartAxis.cxx,v <-- VTK/GUISupport/Qt/Chart/vtkQtChartAxis.cxx new revision: 1.8; previous revision: 1.7 |
(0016463) Alan Scott (manager) 2009-05-14 21:32 |
Are you sure you got it all checked in? I see that we now have ticks and tick labels on the left axis, but the range is still 1.0e-4 to 1. Thus, we are still loosing part of the range we want. |
(0016470) Utkarsh Ayachit (administrator) 2009-05-15 09:12 |
When using log scale, make sure that the end points are indeed as specified by the range rather than the closest power of 10. /cvsroot/ParaView3/ParaView3/VTK/GUISupport/Qt/Chart/vtkQtChartAxis.cxx,v <-- VTK/GUISupport/Qt/Chart/vtkQtChartAxis.cxx new revision: 1.9; previous revision: 1.8 |
(0016491) Alan Scott (manager) 2009-05-15 18:59 |
Great, that fixed it. Tested local server. |
Notes |
Issue History | |||
Date Modified | Username | Field | Change |
2009-05-13 20:08 | Alan Scott | New Issue | |
2009-05-14 07:39 | Utkarsh Ayachit | Status | backlog => tabled |
2009-05-14 07:39 | Utkarsh Ayachit | Assigned To | => Utkarsh Ayachit |
2009-05-14 07:39 | Utkarsh Ayachit | Target Version | => 3.6 |
2009-05-14 10:35 | Utkarsh Ayachit | Note Added: 0016437 | |
2009-05-14 10:35 | Utkarsh Ayachit | Status | tabled => @80@ |
2009-05-14 10:35 | Utkarsh Ayachit | Fixed in Version | => 3.6 |
2009-05-14 10:35 | Utkarsh Ayachit | Resolution | open => fixed |
2009-05-14 21:32 | Alan Scott | Note Added: 0016463 | |
2009-05-14 21:32 | Alan Scott | Status | @80@ => @20@ |
2009-05-14 21:32 | Alan Scott | Resolution | fixed => reopened |
2009-05-15 09:12 | Utkarsh Ayachit | Note Added: 0016470 | |
2009-05-15 09:12 | Utkarsh Ayachit | Status | @20@ => @80@ |
2009-05-15 09:12 | Utkarsh Ayachit | Resolution | reopened => fixed |
2009-05-15 18:59 | Alan Scott | Note Added: 0016491 | |
2009-05-15 18:59 | Alan Scott | Status | @80@ => closed |
2011-01-13 17:00 | Source_changeset_attached | => VTK master a2bd8391 | |
2011-01-13 17:00 | Source_changeset_attached | => VTK master 020ef709 |
Issue History |