View Issue Details [ Jump to Notes ] | [ Print ] | ||||||||
ID | Project | Category | View Status | Date Submitted | Last Update | ||||
0012166 | ParaView | Feature | public | 2011-05-06 18:33 | 2011-06-24 20:23 | ||||
Reporter | Alan Scott | ||||||||
Assigned To | Robert Maynard | ||||||||
Priority | normal | Severity | minor | Reproducibility | have not tried | ||||
Status | closed | Resolution | fixed | ||||||
Platform | OS | OS Version | |||||||
Product Version | |||||||||
Target Version | Fixed in Version | 3.12 | |||||||
Summary | 0012166: CTH file reader needs to only open files once | ||||||||
Description | The CTH reader needs to only open files once. At present, files are opened three times. As per an e-mail from Robert, Every Process will do the following during Request Information: • Open the input file and read 7 bits • Close input file • If Time Series o Will query the file system to see the number of files in the time series. The net result is that we will call access() on each file in the time series plus 3 to see if we have read access and that file exists. At worse we will ask for we have read access on 3 files that don't exist. • Now we will read the first file in the time series for the information. o We read the majority of the file ( 86% in this case ) o We do 147 relative seeks o We do 22 absolute seeks from the start of the file Now the primary issue is that the Request Information step is called 3 times before the GUI Panel is displayed, causing all the above file IO to happen 3 times on each process. I also have attached a basic log of the read step, and I can generate an even more detailed log if needed. | ||||||||
Tags | No tags attached. | ||||||||
Project | |||||||||
Topic Name | |||||||||
Type | |||||||||
Attached Files | |||||||||
Relationships | |
Relationships |
Notes | |
(0026736) Robert Maynard (developer) 2011-06-07 08:57 |
The Meta Information is only read twice once in RequestDataObject and RequestInformation. c377139 Fixes Bug 0012166 we know only parse the meta information once. 850b225 BUG: Fix an issue where spy plot data wasn't updating for each timestep. |
(0026889) Alan Scott (manager) 2011-06-24 20:23 |
I tested this client/remote server, reading CTH. Trunk, Linux. |
Notes |
Issue History | |||
Date Modified | Username | Field | Change |
2011-05-06 18:33 | Alan Scott | New Issue | |
2011-05-06 18:35 | Alan Scott | Target Version | => 3.12 |
2011-05-30 10:45 | Robert Maynard | Assigned To | => Robert Maynard |
2011-05-30 10:45 | Robert Maynard | Status | backlog => tabled |
2011-06-07 08:57 | Robert Maynard | Note Added: 0026736 | |
2011-06-07 08:57 | Robert Maynard | Status | tabled => @80@ |
2011-06-07 08:57 | Robert Maynard | Fixed in Version | => 3.12 |
2011-06-07 08:57 | Robert Maynard | Resolution | open => fixed |
2011-06-16 13:10 | Zack Galbreath | Category | Feature Request => Feature |
2011-06-24 20:23 | Alan Scott | Note Added: 0026889 | |
2011-06-24 20:23 | Alan Scott | Status | customer review => closed |
Issue History |